LogTemp Version history

bulletVersion 2.24.0.92  04 Oct 2009
bulletAdded support for UV Index Meter by Hobby-Boards, also graphs
bulletAdded own temperature correction for HIH-4010 humidity sensor
bulletCorrected XML settings (disabled)
bulletMySQL data saved with two decimals instead of one decimal
bulletCounter readings enhanced when reading both pages from the same chip
bulletChanged sensor number in xAP messages in order to have always the same number if possible
bulletMinor adjustments
bulletVersion 2.23.0.90  11 May 2009
bulletAdded own temperature correction for HIH-4000 humidity sensor
bulletFixed calculation for average (H24) values
bulletVersion 2.22.0.89  11 Apr 2009
bulletService release, no new features
bulletFixed Energy Counter selection visibility for DS2423 sensor
bulletChanged max value for pulses / kWh, was 6000 and now is 32000 pulses / kWh
bulletVersion 2.22.0.88  05 Apr 2009
bulletAdded Energy Consumption (kWh) Counter with DS2423 chip
bulletDay/week/month Energy pictures with line or bar graph
bulletAdded DailyHTML file (daily last.htm)
bulletAdded xAP reporting with TSC schema (http://www.xapautomation.org)
bulletIncreased max picture size from 800x800 to 2k x 2k
bulletChanges to program/sensor settings will be saved right away
bulletMinor adjustments
bulletVersion 2.21.0.78  20 Jan 2008
bulletMySQL datetime field also possible as UTC
bulletAdded Solar + VAD sensortype for DS2438
bulletAdded possibility to confirm program closure
bulletAdded possibility to send 10 own FTP files
bulletCorrected ocassional excessive CPU load
bulletMinor adjustments
bulletVersion 2.20.0.73  25 Nov 2007
bulletFTP dataport can be assigned via logtemp.ini file, if computer has several simultaneous ftp programs. Define port range as follows:
[FTP]
DataPortRangeStart=5000
DataPortRangeEnd=5999
bulletCorrected history data reading
bulletCorrected event scheduling when Daylight Saving Time changes
bulletExpanded manual scaling for thermocouples
bulletCorrected MySQL saving, was stopping after first error
bulletFile size limit now max 400 000 lines, was 100 000
bulletMinor adjustments
bulletVersion 2.19.0.70  28 Jun 2007
bulletSupport for thermocouples (E, J, K, R, S and T type) using DS2760
bulletSupport for DS2760 internal temperature measuring
bulletDS2438 Vsens negative values removed
bulletAdded 15 and 30 sec measuring intervals
bulletCorrected MySQL password saving
bulletVersion 2.18.0.66  24 May 2007
bulletCorrected events scheduling when using Fixed times
bulletNew correction to DS2438 Vsens negative values
bulletVersion 2.18.0.65  14 May 2007
bulletSupport for DS2406 switches, can be used for alarm events
bulletLess overhead with MySQL. Error messages also saved (SQL script)
bulletMore definitions for last.htm, also validation can be added
bulletDS2423 absolute values shown in the list
bulletCorrected Fahrenheit virtual sensor
bulletCorrected month values when measuring only during some days
bulletCorrected DS2438 Vsens negative values
bulletMinor adjustments
bulletVersion 2.17.0.64  14 Jan 2007
bulletSupport fo MySQL™ database
bulletMySQL servers 3.xx/4.x/5.x supported
bulletNo MySQL libraries (libmysql.dll) are required
bulletSupport for DS2438 voltage measurements (VAD)
bulletSupport for DS2405 switches, can be used for alarm events
bulletAbsolute or difference values for DS2423 counter
bulletMinor adjustments
bulletVersion 2.16.0.61  02 Dec 2006
bulletMySQL test version, works until 31 Jan 2007.
bulletMeasurements can be saved to MySQL™ database
bulletMySQL servers 3.xx/4.x/5.x supported
bulletNo MySQL libraries (libmysql.dll) are required
bulletMinor adjustments
bulletVersion 2.15.0.59  01 Apr 2006
bulletSupport for DS2409 based 1-Wire hubs, only one level
bulletSelection of picture time scale improved
bulletDay, Week and Month pictures saved for all types
bulletPicture title optional
bulletFTP tranfer moved to background process
bulletFTP BandWidth can be controlled
bulletImproved FTP server directory selection
bulletRSS feed from last measurements
bulletMethod of reading of sensors changed
bulletDS2423 counter page can be selected
bulletError list can be cleared
bulletVersion 2.14.0.50  29 Jan 2006
bulletService release, no new features
bulletCorrected scaling of the saved pictures
bulletVersion 2.14.0.48  12 Dec 2005
bulletService release, no new features
bulletCorrected size of the saved pictures
bulletVersion 2.14.0.47  11 Dec 2005
bulletService release, no new features
bulletCorrected scaling of the saved pictures
bulletCorrected DS1820 family (1820, 18S20 and 1920) negative temperature calculations. Calculated value was 0.5° C too low.
bulletVersion 2.14.0.46  04 Dec 2005
bulletAdded support for barometer (DS2438 + MPX4115A, Bitson model from www.hobby-boards.com)
bulletAdded support for combined humidity and solar radiation detector
bulletAdded support for DS2423 subtype: general counter, anemometer or rain gauge. Supported anemometer is AAG's 1-Wire Wind Instrument (ver 3.0) There is no picture (yet) generated from these values
bulletThere is only one picture with selectable time scale for temperatures shown. Day, week and month temperatures can be saved at the same time
bulletSensor list has units for each sensor in a separate column
bulletMeasuring events can be adjusted also to the fixed times, i.e. 20 min interval and events at 00:00, 00:20, 00:40, 01:00 etc. Fixed times are allways based on 00:00
bulletAlarm email message can have sensor name and value in message SUBJECT
bulletFTP password will be saved without encryption due to several problems
bulletCorrection to DS2438 temperature measuring for spikes
bulletCorrection for reading big *.txt files for sensor history
bulletEnhanced error messages for 1-Wire network problems
bulletMinor adjustments
bulletVersion 2.13.0.43  12 Jul 2005
bulletAdded support for DS2423 counters. These can be used for Lightning Detectors etc. There is no picture (yet) generated from these values
bulletAdded possibility send alarm messages via email. LogTemp sends alarm messages to SMTP Server. Several send profiles can be defined
bulletEmail support can be used also for sending text messages (SMS) to mobile (GSM) phones. LogTemp has native support for two internet based commercial SMS gateways, Clickatell and PsWin. You need to open an account with the gateway before sending SMS messages. More information about the prices etc. can be found from those pages
bulletImproved FTP performance
bulletMinor adjustments
bulletVersion 2.12.0.42  05 Jun 2005
bulletService release, no new features
bulletChanged BINARY/ASCII identification for FTP transfer
bulletCorrected activation of OK button for settings dialog
bulletVersion 2.12.0.39  29 May 2005
bulletAdded support to Solar Radiation (DS2438 + photodiode) Radiation is measured in mill volts and shown in percent (max 250 mV). Results will be show'n in humidity graph
bulletAdded Dew point calculation for humidity sensors
bulletAdded support for temperature measurements for DS2438 sensors.
bulletSensor list will identify each sensor with one character in the beginning of the row. (T=Temperature, H=Humidity, S=Solar radiation)
bulletSubtype for each DS2438 sensor must be defined (humidity or solar). All unknown sensors will added to list where they can be picked via menu or via right mouse click
bulletList of alarming sensor will be show'n only when needed
bulletSupported (for searching) sensor types can be selected via setup.
bulletAdded encoding selection for XML file
bulletMinor adjustments
bulletVersion 2.11.0.38  10 Apr 2005
bulletCorrected FTP password saving. NOTE: Set password before
first transfer
bulletAdded support to DS2438 + HIH 3610 based humidity sensors
bulletHumidity picture for day, week or month
bulletAdded last.csv and last.xml files
bulletColumns for csv and xml files can be defined
bulletMonth and Day also using short names for titles
bulletMinor adjustments
bulletVersion 2.10.0.37  22 Aug 2004
bulletAdded FTP Client
bulletAdded table definitions for last.htm file
bulletMinor changes
bulletVersions 2.8 - 2.9
bulletBeta testing with FTP Client
bulletVersion 2.7.0.31  23 Mar 2004
bulletService release, no new features
bulletCorrection to some ini-file settings
bulletVersion 2.7.0.30  15 Mar 2004
bulletError-correction parameters for each sensor
bulletTitle fonts and location can be changed
bulletCorrection to save manual scaling
bulletCorrection to Alarms-list update
bulletMore error checking to html-file save method
bulletMinor changes
bulletVersion 2.6.0.29  29 Feb 2004
bulletAlarm limits defined for sensors. Command with parameters and/or sound file to run can be defined for alarm
bulletColours can be changed
bulletScaling can be set manually
bulletVirtual sensors. Shows difference between two (hard) sensors
bulletMore error checking to picture saving method
bulletMinor changes
bulletVersion 2.5.0.28  18 Jan 2004
bulletCorrection to DS18B20 and DS1822 negative temperature calculations
bulletHistory line in the week picture starts from divider
bulletSmall layout changes
bulletVersion 2.4.0.27  5 Jan 2004
bulletCorrection to Week picture, one day offset after the year has changed
bulletVersion 2.4.0.26  5 Jan 2004
bulletCorrection to read history data when year has changed
bulletVersion 2.4.0.25  15 Dec 2003
bulletSupport to externally powered sensors
bulletError messages can be saved
bulletCorrection to save sensor properties, history line
bulletVersion 2.3.0.24  02 Dec 2003
bulletProgram localized using the external lng-language file
bulletSome small layout changes
bulletAverage value (H24) calculated
bulletThe units can be changed to Fahrenheit (normally Celsius)